Explosion-proof Zirconia Oxygen Analyzer

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Beijing
Validity to: Long-term effective
Last update: 2020-08-01 10:31
Browse the number: 181
inquiry
Company Profile
 
 
Product details

Description

The explosion-proof zirconia oxygen analyzer not only is a practical and reliable automatic analytical instrument and also the explosion-proof zirconia oxygen analyzer has the characteristics of high sensitivity, good reproducibility and stability, wide range, automatic switching, fast response and continuous online measurement. Therefore, the Explosion-proof Zirconia Oxygen Analyzer can quickly and correctly detect and analyze the flue gas content generated by combustion equipment such as boilers, kiln and heating furnaces that to achieve low-oxygen combustion control, to achieve energy-saving purposes, reduce environmental pollution.


Application
The explosion-proof zirconia oxygen analyzer is mainly used in: coal-fired power plants, waste incineration power plants, biomass power plants, sulfuric acid plants, chemical plant boilers, hazardous waste treatment boilers, heating station boilers, steel plants, steel mills, petroleum Pipeline pressure station boilers and other fields.


Main Features
★ No special ground wire required.

★ High accuracy and wide range ratio.
★ Zirconia probe wear resistance and corrosion resistance.
★ Strong resistance to field interference.
★ Easy to install, the response is fast and widely used.

★ Convenient replacement of components, easy maintenance, and reduced use cost.


Specification

Items

Specifications

Oxygen concentration:

0.001~100 vol%

Output signal:

4~20mA DC (maximum load resistance 750Ω)

Setting range:

0~20.6 vol% (0~30% can be set)

Digital communications:

Support Modbus 232/485 and Ethernet (selectable)

Heating time:

Approx. 20 min.

Repeatability:

±0.5vol% maximum value of set range.

Zero drift:

1.5 vol% maximum value of set range (60 days)

Response time:

Response of 90% within 5 seconds. (Measured after gas is introduced from standard gas inlet and oxygen signal starts changing).

Power supply:

220±10%VAC

Installation:

Flange mounting

Limit output:

Provide settable upper and lower limit outputs (optional)

Temperature control accuracy:

0~700℃ (Floating temperature calculation)


Equipment system accuracy:

±1%F.S.

Digit display mode:

4 bit LED nixie tube display

Operation:

Menu button operation

Calibration operation:

Three parameters on-line calibration

Equipment power:

Approx. 10W (Excluding heating power)

Heating power:

50W (average), able to supply maximum 150W power output

Environmental conditions:

Ambient temperature 0~70℃, relative humidity ≤ 90%

Protection level:

IP65

Electrical interface:

M20

Explosion-proof level:

EXdII ct6 GB (only for explosion-proof type product)

Detector length:

180mm\400mm\600mm\800mm\1000mm\1200mm\1500mm (customizable)

(Note: Detector length is from the detector tip to flange)